Related Experiment Video
Updated: Feb 15, 2026

A Murine Model of Ischemic Retinal Injury Induced by Transient Bilateral Common Carotid Artery Occlusion
Published on: November 12, 2020
Bilateral arterial occlusions masking retinitis in a HIV-positive male
Kalpana Babu1, Bhagya Sudheer1, Krishna R Murthy1
1Prabha Eye Clinic and Research Center, Vittala International Institute of Ophthalmology, Bengaluru, Karnataka, India.
Abstract:
We report an interesting case of 36-year-old HIV-positive male with uveitis, cilioretinal artery occlusion in OD, and superotemporal branch retinal artery occlusion in OS. Hypercoagulability, cardiovascular, and rheumatologic workups were unremarkable. Aqueous taps were negative for toxoplasma, viruses, and MTb by multiplex polymerase chain reaction. Patches of retinitis were seen on clearing of retinal edema. Serology was positive for toxoplasma and rickettsia. Management included doxycycline, azithromycin, bactrim DS, and oral steroids. Vision improvement to 6/60 and 6/24 in OD and OS refer to the right eye and left eye, respectively, were noted at 4-month follow-up. Infections should be considered in arterial occlusions associated with inflammation in HIV-positive individuals.
More Related Videos
09:02A Large Animal Model for Acute Kidney Injury by Temporary Bilateral Renal Artery Occlusion
Published on: February 2, 2021
07:46Bilateral Common Carotid Artery Occlusion as an Adequate Preconditioning Stimulus to Induce Early Ischemic Tolerance to Focal Cerebral Ischemia
Published on: May 9, 2013
Related Concept Videos
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Infertility in Males
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Disorders of the Male Reproductive System
Prostate disorders are another major concern. These conditions can impair urinary flow due to the prostate's location around the urethra....
The Y Chromosome Determines Maleness
Evolution