A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
A practical background correction method for an immediately repeated first-pass radionuclide angiography
Lien-Hsin Hu1, Liang-Chih Wu1, Chien-Ying Lee1
1Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
A new method corrects background interference in first-pass radionuclide angiography (FPRNA) after suboptimal bolus injections. This technique improves the accuracy of ejection fraction measurements, avoiding repeat studies and ensuring reliable cardiac function assessment.
Area of Science:
- Nuclear Medicine
- Cardiovascular Imaging
- Radiology
Background:
- First-pass radionuclide angiography (FPRNA) requires satisfactory bolus injections for accurate results.
- Suboptimal injections lead to background interference, often necessitating study rescheduling.
- A novel protocol was developed to correct pre-existing background activity.
Purpose of the Study:
- To develop and validate a method for correcting background activity in FPRNA.
- To assess the impact of background correction on ejection fraction (EF) measurements.
- To improve the reliability of FPRNA by avoiding repeat procedures.
Main Methods:
- Seventy-four patients undergoing same-day bone scan and FPRNA were analyzed.
- Ejection fraction (EF) was calculated from initial and repeated injections, with and without background correction.
- A subset of patients had clearance constants determined for enhanced background correction.
Main Results:
- The corrected ejection fraction (EF2') showed significantly smaller mean differences compared to the uncorrected EF2 for both left and right ventricles (LV and RV).
- Mean differences for LV were 1.6 ± 2.1% (corrected) vs. 3.1 ± 2.0% (uncorrected).
- Mean differences for RV were 1.8 ± 1.8% (corrected) vs. 2.2 ± 1.9% (uncorrected).
Conclusions:
- Immediate re-administration of bolus injection in FPRNA can underestimate LVEF and RVEF.
- The developed correction method provides superior results compared to uncorrected data.
- This protocol enhances the accuracy of FPRNA, particularly when initial injections are suboptimal.
Related Concept Videos
First Pass Effect
Depending on the route of administration, drugs can be metabolized in the liver, intestine, lungs, and vasculature. Orally administered drugs are first absorbed through the...
Distance Corrections
Power Factor Correction
Background and Environment Affect Phenotype
An example of how genetic background affects phenotype can be seen in horses. The Extension gene in horses is responsible for their coat color. A wild-type gene (EE) produces black pigment in the coat, while a mutant gene (ee) produces red pigment. A...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Single-pass Transmembrane Proteins