Related Experiment Video
Updated: Feb 14, 2026

A Standardized Method for Measuring Internal Lung Surface Area via Mouse Pneumonectomy and Prosthesis Implantation
Published on: July 26, 2017
Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study.
David Peñarrocha-Oltra1, Blanca Serra-Pastor2, José-Carlos Balaguer-Martí3
1Assistant Professor. Oral Surgery Section, Department of Stomatology, Valencia University Medical and Dental School. Valencia, Spain.
A novel flexible screw abutment system for dental implants shows promising results for immediate loading. This system offers a reliable, passive fit for interim prostheses, enhancing patient and dentist satisfaction.
Area of Science:
- Dental Implantology
- Prosthodontics
- Biomaterials Engineering
Background:
- Immediate loading protocols are increasingly favored for dental implant rehabilitation due to patient convenience.
- Conventional loading techniques can be time-consuming and less comfortable for patients.
Purpose of the Study:
- To evaluate a novel system of abutments with flexible screws for immediate dental implant loading.
- To assess implant survival, marginal bone loss, and patient/dentist satisfaction with this new system.
Main Methods:
- A preliminary study involved 8 patients receiving dental implants with immediate loading using flexible screw abutments.
- Analysis included implant survival rates, marginal bone loss measurements, and satisfaction scores.
Main Results:
- 35 implants were immediately loaded with the flexible screw abutment system.
- Implant survival rate after 12 months was 95.8%.
- Mean marginal bone loss was 0.51 ± 0.12 mm, with high patient (9.1) and dentist (8.5) satisfaction.
Conclusions:
- The flexible screw abutment system provides a viable alternative for immediate dental implant loading.
- It facilitates the quick and straightforward fabrication of a stable, passive-fit interim prosthesis.
- This system demonstrates efficacy and high satisfaction in clinical application.
More Related Videos
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
Published on: February 14, 2015
12:01Techniques for Processing Eyes Implanted With a Retinal Prosthesis for Localized Histopathological Analysis
Published on: August 2, 2013
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Case Studies