Is dynamic locking plate(Targon FN) a better choice for treating of intracapsular hip fracture? A meta-analysis
Hao Yin1, Zhengjun Pan1, Hua Jiang1
1Department of Orthopaedics, The Third Affiliated Hospital of AnHui Medical University, China.
Purpose:
The aim of this study was to assess the outcomes of dynamic locking plate (Targon FN) and other alternative implant (cannulated cancellous screws or sliding hip screw) for treating of intracapsular hip fracture.
Methods:
Relevant clinical trials on the dynamic locking plate and alternative implant treatment for intracapsular hip fracture were retrieved through searching the databases, PubMed, Embase and the Cochrane Central Register of Controlled Trials up to August 2017. Studies that investigated the comparing effectiveness or complications between both groups and provided sufficient data of interest were included in this meta-analysis.
Results:
Four studies involving 385 intracapsular hip fractures were included. The differences in nonunion [odds ratio (OR) 0.16,95% confidence interval (CI) 0.05-0.49], revision (OR 0.56, 95%CI 0.32-0.96) and replacement rate (OR 0.26, 95%CI 0.10-0.69) were statistically significant between dynamic locking plate and alternative implant group. There was no statistically significant difference in osteonecrosis (OR1.73, 95%CI0.59-5.02), cut-out (OR0.89,95%CI0.23-3.46)and non orthopaedics complication rate (OR0.73, 95% CI 0.38-1.41).
Conclusions:
The available evidence indicate that dynamic locking plate offers a superior outcome in comparison with alternative implants and reduces the nonunion, revision and replacement rates for treating intracapsular hip fractures, but does not affect the osteonecrosis, cutout and non-orthopadeics complication rate. Decisions should be made in accordance with specific conditions for clinical application.
More Related Videos
06:58Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Mate Choice
Directing Effect of Substituents: meta-Directing Groups
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Personal Choice and Fate Attributions
Dynamic Equilibrium
