Free-breathing dynamic contrast-enhanced MRI for assessment of pulmonary lesions using golden-angle radial sparse
Lihua Chen1,2, Daihong Liu1, Jiuquan Zhang1
1Department of Radiology, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, China.
Background:
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been shown to be a promising technique for assessing lung lesions. However, DCE-MRI often suffers from motion artifacts and insufficient imaging speed. Therefore, highly accelerated free-breathing DCE-MRI is of clinical interest for lung exams.
Purpose:
To test the performance of rapid free-breathing DCE-MRI for simultaneous qualitative and quantitative assessment of pulmonary lesions using Golden-angle RAdial Sparse Parallel (GRASP) imaging.
Study Type:
Prospective.
Population:
Twenty-six patients (17 males, mean age = 55.1 ± 14.4) with known pulmonary lesions.
Field Strength/Sequence:
3T MR scanner; a prototype fat-saturated, T1 -weighted stack-of-stars golden-angle radial sequence for data acquisition and a Cartesian breath-hold volumetric-interpolated examination (BH-VIBE) sequence for comparison.
Assessment:
After a dual-mode GRASP reconstruction, one with 3-second temporal resolution (3s-GRASP) and the other with 15-second temporal resolution (15s-GRASP), all GRASP and BH-VIBE images were pooled together for blind assessment by two experienced radiologists, who independently scored the overall image quality, lesion delineation, overall artifact level, and diagnostic confidence of each case. Perfusion analysis was performed for the 3s-GRASP images using a Tofts model to generate the volume transfer coefficient (Ktrans ) and interstitial volume (Ve ).
Statistical Tests:
Nonparametric paired two-tailed Wilcoxon signed-rank test; Cohen's kappa; unpaired Student's t-test.
Results:
15s-GRASP achieved comparable image quality with conventional BH-VIBE (P > 0.05), except for the higher overall artifact level in the precontrast phase (P = 0.018). The Ktrans and Ve in inflammation were higher than those in malignant lesions (Ktrans : 0.78 ± 0.52 min-1 vs. 0.37 ± 0.22 min-1 , P = 0.020; Ve : 0.36 ± 0.16 vs. 0.26 ± 0.1, P = 0.177). Also, the Ktrans and Ve in malignant lesions were also higher than those in benign lesions (Ktrans : 0.37 ± 0.22 min-1 vs. 0.04 ± 0.04 min-1 , P = 0.001; Ve : 0.26 ± 0.12 vs. 0.10 ± 0.00, P = 0.063).
Data Conclusion:
This feasibility study demonstrated the performance of high spatiotemporal resolution free-breathing DCE-MRI of the lung using GRASP for qualitative and quantitative assessment of pulmonary lesions.
Level Of Evidence:
2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:459-468.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Breathing
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Parallel Processing