Recurrent pregnancy loss is newly defined as more than two consecutive miscarriages. Recurrent pregnancy loss occurs in <5% of total pregnancies. The cause in approximately 40-60% of recurrent pregnancy loss cases remains elusive and must be determined. We investigated two unrelated Iranian consanguineous families with recurrent pregnancy loss. We performed exome sequencing using DNA from a miscarriage tissue and identified a homozygous NOP14 missense variant (c.[136C>G];[136C>G]) in both families. NOP14 is an evolutionally conserved protein among eukaryotes and is required for 18S rRNA processing and 40S ribosome biogenesis. Interestingly, in zebrafish, homozygous mutation of nop14 (possibly loss of function) resulting from retrovirus-mediated insertional mutagenesis led to embryonic lethality at 5 days after fertilization, mimicking early pregnancy loss in humans. Similarly, it is known that the nop14-null yeast is inviable. These data suggest that the homozygous NOP14 mutation is likely to cause recurrent pregnancy loss. Furthermore, this study shows that exome sequencing is very useful to determine the etiology of unsolved recurrent pregnancy loss.
Related Concept Videos
Histone Variants at the Centromere
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.