Related Experiment Video
Updated: Feb 14, 2026

Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
Active Localization and Tracking of Needle and Target in Robotic Image-Guided Intervention Systems
Mark Renfrew1, Mark Griswold2, M Cenk Çavuşoğlu1
1Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, Ohio, USA.
Abstract:
This paper describes a framework of algorithms for the active localization and tracking of flexible needles and targets during image-guided percutaneous interventions. The needle and target configurations are tracked by Bayesian filters employing models of the needle and target motions and measurements of the current system state obtained from an intra-operative imaging system which is controlled by an entropy-minimizing active localization algorithm. Versions of the system were built using particle and unscented Kalman filters and their performance was measured using both simulations and hardware experiments with real magnetic resonance imaging data of needle insertions into gel phantoms. Performance of the localization algorithms is given in terms of accuracy of the predictions and computational efficiency is discussed.
Related Concept Videos
Site-Targeted Drug Delivery Systems: Polymeric Carriers
Modified-Release Drug Delivery Systems: Site-Targeted
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions
Local Anesthetics: Chemistry and Structure-Activity Relationship
Modified-Release Drug Delivery Systems: Stimuli-Activated