Phagocytosis by Sertoli Cells: Analysis of Main Phagocytosis Steps by Confocal and Electron Microscopy

Marina G Yefimova1,2, Nadia Messaddeq3,4,5,6, Annie-Claire Meunier1

  • 1Laboratoire Signalisation et Transports Ioniques Membranaires, Université de Poitiers/CNRS, Poitiers, France.

Related Concept Videos

Phagocytosis00:41

Phagocytosis

Cells pull particles inward and engulf them in spherical vesicles in an energy-requiring process called endocytosis. Phagocytosis (“cellular eating”) is one of three major types of endocytosis. Cells use phagocytosis to take in large objects—such as other cells (or their debris), bacteria, and even viruses.
93.3K
Phagocytosis00:41

Phagocytosis

Cells pull particles inward and engulf them in spherical vesicles in an energy-requiring process called endocytosis. Phagocytosis ("cellular eating") is one of three major types of endocytosis. Cells use phagocytosis to take in large objects, such as other cells (or their debris), bacteria, and even viruses.
The objective of phagocytosis is often destruction. Cells use phagocytosis to eliminate unwelcome visitors, like pathogens (e.g., viruses and bacteria). Many immune system cells,...
8.2K
Phagocytosis of Apoptotic Cells01:17

Phagocytosis of Apoptotic Cells

Cells undergoing apoptosis form apoptotic bodies that must be removed immediately to prevent inflammation, autoimmune diseases, and necrosis. Phagocytosis is carried out by professional phagocytes such as macrophages or  immature dendritic cells. Non-professional phagocytes such as  epithelial cells and fibroblasts also take part in this process; however, they are not as effective as professional phagocytes. 
Normal cells contain receptors that prevent them from being recognized...
5.2K
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
21.3K
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
15.5K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.6K