Related Experiment Video
Updated: Feb 14, 2026

Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Diurnal Variations of Peripapillary and Macular Vessel Density in Glaucomatous Eyes Using Optical Coherence
Kaweh Mansouri1,2, Harsha L Rao3, Kirsten Hoskens1
1Glaucoma Research Center, Montchoisi Clinic, Swiss Vision Network, Lausanne, Switzerland.
Purpose:
The purpose of this study was to investigate the diurnal variation in peripapillary and macular vessel density (VD) measurements using optical coherence tomographic angiography (OCT-A) and its correlation to intraocular pressure (IOP) changes in glaucoma patients.
Methods:
Prospective, observational cross-sectional study including 37 patients (74 eyes; age, 63.8±12.9 y) with open-angle glaucoma. OCT-A imaging and IOP measurements were performed at 08:00, 11:00, 14:00, and 16:00 timepoints on a single day. At each timepoint, 2 scan protocols were used to generate 3-dimensional en face OCT angiograms: 4.5×4.5-mm scan centered on the optic nerve head and 6×6-mm scan centered on the fovea. For each scan mode, the "radial peripapillary capillary" segment, composed of the vasculature of the retinal nerve fiber layer and ganglion cell layer, was calculated. Two trained readers reviewed OCT-A image quality. Only scans with signal strength intensity (SSI) higher than 46 and without image artifacts interfering with measurements were included. Variation in VD measurements assessed using analysis of variance (ANOVA) and the association between VD and IOP changes assessed using linear mixed modeling methods.
Results:
The optic nerve head and peripapillary VD measurements at 14:00 and 16:00 timepoints were greater than the measurements at 08:00 and 11:00 timepoints. The 14:00 and 16:00 VD measurements were statistically significantly greater (P<0.05) than the 08:00 measurements for the whole en face (50.1% and 50.1% vs. 49.4%), inside disc (50.6% and 50.5% vs. 49.6%), and average peripapillary (58.2% and 58.5% vs. 57.5%) VDs. The macular VD measurements at the 14:00 timepoint were greater than the measurements at 08:00 and 11:00 timepoints. Changes in VD were significantly associated with changes in SSI but not IOP.
Conclusions:
Diurnal changes in OCT-A-measured VD in glaucoma patients were small and clinically insignificant. These changes were not associated with IOP changes.
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...

