Related Experiment Video
Updated: Feb 14, 2026

Establishing a Severe Corneal Inflammation Model in Rats Based on Corneal Epithelium Curettage Combined with Corneal Sutures
Published on: November 22, 2024
Dynamic corneal deformation response and integrated corneal tomography.
Marcella Q Salomão1, Ana Luisa Hofling-Lima2, Fernando Faria-Correia3
1Department for Ophthalmology, The Federal University of Sao Paulo, Sao Paulo, Brazil; Rio de Janeiro Corneal Tomography and Biomechanics Study Group; Department of Ophthalmology, Instituto De Olhos Renato Ambrósio and VisareRIO, Rio de Janeiro, Brazil.
Measuring corneal biomechanical properties is difficult but crucial for detecting early ectatic corneal diseases. The Corvis ST tonometer offers valuable clinical applications for these biomechanical measurements.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Corneal Science
Background:
- Accurate measurement of corneal biomechanical properties remains a significant clinical challenge.
- Corneal biomechanics plays a vital role in diagnosing and managing various ocular conditions.
- Early detection of ectatic corneal diseases is essential for effective patient management.
Purpose of the Study:
- To review the clinical applications of biomechanical measurements obtained using the Corvis ST dynamic non-contact tonometer.
- To highlight the utility of the Corvis ST in identifying early-stage ectatic corneal diseases.
- To provide an overview of current and potential uses of Corvis ST in clinical practice.
Main Methods:
- Review of existing literature and clinical studies on the Corvis ST tonometer.
- Analysis of data generated by the Corvis ST regarding corneal biomechanical parameters.
- Evaluation of the diagnostic performance of the Corvis ST for ectatic corneal diseases.
Main Results:
- The Corvis ST provides objective and repeatable measurements of corneal biomechanical properties.
- Corvis ST parameters show promise in differentiating healthy corneas from those with early ectasia.
- Clinical applications include enhanced detection of subclinical keratoconus and other corneal ectasias.
Conclusions:
- The Corvis ST dynamic non-contact tonometer is a valuable tool for assessing corneal biomechanics.
- Its applications extend to the early detection and monitoring of ectatic corneal diseases.
- Further research can expand the clinical utility of Corvis ST in ophthalmology.
Related Concept Videos
Plastic Deformations
Plastic Deformations
Temperature Dependent Deformation
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Deformation in a Circular Shaft

