An Argument for Self-Report as a Reference Standard in Audiology
Andrew J Vermiglio1, Sigfrid D Soli2, Xiangming Fang3
1Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC.
Self-report is a valid reference standard for audiology diagnostic studies. The Hearing-in-Noise Test (HINT) shows higher accuracy than pure-tone thresholds for detecting speech-recognition-in-noise disorders in individuals with normal audiograms.
Area of Science:
- Audiology
- Diagnostic Accuracy Studies
- Hearing Science
Background:
- Pure-tone thresholds are traditionally the gold standard in audiology.
- Discrepancies exist between audiogram results and perceived hearing ability, particularly in noisy environments.
- This highlights a need for alternative reference standards in audiology diagnostics.
Purpose of the Study:
- To advocate for the use of self-report as a reference standard in audiology diagnostic accuracy studies.
- To review literature on pure-tone thresholds and self-report as reference standards.
- To assess the diagnostic accuracy of pure-tone thresholds and the Hearing-in-Noise Test (HINT) for identifying speech-recognition-in-noise disorders.
Main Methods:
- Literature review on reference standards in audiology.
- Evaluation of two groups: King-Kopetzky syndrome (KKS) with self-reported hearing difficulties and a control group.
- Diagnostic accuracy assessment using self-report as the reference standard, comparing pure-tone thresholds and HINT performance via sensitivity, specificity, and ROC curves.
Main Results:
- Self-report has been previously utilized as a reference standard for individuals with normal audiograms experiencing speech-in-noise difficulties.
- The HINT demonstrated statistically significant differences between KKS and control groups, unlike pure-tone thresholds.
- The HINT Composite score showed higher sensitivity (88%) and a larger area under the curve (AUC=0.87) compared to pure-tone average (PTA; 28% sensitivity, AUC=0.51).
Conclusions:
- Self-report is a justifiable reference standard for evaluating the diagnostic accuracy of speech-recognition-in-noise tests.
- In individuals with normal pure-tone thresholds, the HINT is more accurate than pure-tone thresholds for diagnosing speech-recognition-in-noise disorders.