Does the Variability of Evoked Tympanic Membrane Displacement Data (V m) Increase as the Magnitude of the Pulse
Sammy J Sharif1, Cherith M Campbell-Bell2, Diederik O Bulters3
1University of Southampton, Hampshire, UK.
Objectives:
Evoked tympanic membrane displacement (TMD) measurements, quantified by V m, record small volume changes in the ear canal following stimulation of the acoustic reflex. V m shows a correlation with intracranial pressure (ICP) and has been proposed as an option to non-invasively measure ICP. The spontaneous pulsing of the tympanic membrane, driven by the cardiovascular pulse, may contaminate the recordings and contribute to high measurement variability in some subjects. This study hypothesised that the larger the spontaneous vascular pulse, the larger the variability in V m.
Materials And Methods:
Spontaneous and evoked TMD data from each ear in the sitting and supine position were recorded from 100 healthy volunteers using the MMS-14 CCFP analyser. ECG was also recorded to identify each heartbeat. Using bespoke software written in Matlab, spontaneous data were analysed to produce average pulse amplitude (PA) waveforms and evoked data were analysed to calculate average V m and its standard deviation. Averaged spontaneous PA was plotted against V m variability and Pearson's correlation coefficient was calculated to test for a significant linear relationship.
Results:
There was a strong positive correlation between PA and V m variability in all conditions: left sitting, r = 0.758; left supine, r = 0.665; right sitting, r = 0.755; right supine, r = 0.513. All were significant at p < 0.001.
Conclusion:
This study shows that large V m variability is associated with a large spontaneous vascular pulse. This suggests that efforts to reduce vascular pulsing from recordings, either by a subtraction technique during post-processing or ECG-gating of the evoking stimulus, may improve reliability of the V m measurement.
More Related Videos
Related Concept Videos
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Increasing Function
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Increased Body Temperature
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Orders of Magnitude
The order of magnitude is simply a way of rounding numbers consistently to the nearest power of 10. This makes doing rough mental math...