Related Experiment Video
Updated: Feb 13, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
An Instrumental Electrode Configuration for 3D Ultrasound Modulated Electrical Impedance Tomography
Abstract:
Ultrasound modulated electrical impedance tomography (UMEIT) is a novel hybrid imaging technique, which utilizes coupling between electric and acoustic modalities. Based on the forward solver along different current directions, an instrumental electrode configuration is proposed for 3D UMEIT. The proposed electrode configuration can produce a similar longitudinal current, making the power density distribution on the x-y plane approximately consistent with the corresponding conductivity distribution. Then, this satisfying power density is adopted to reconstruct a higher-resolution conductivity distribution. Therefore, the proposed electrode configuration contributes to improving the image reconstruction quality of UMEIT. Also, to clearly demonstrate its meaning in theory, the forward solver results are analyzed from an electrical point of view. In addition, the nonlinear partial differential equation (PDE) relating the power density to the measured data is derived again with a more reasonable expression. Finally, simulation with realistic geometry model of human breast is done and feasibility verifying experiment is made. Both simulation and experimental results validate the feasibility of the proposed electrode configuration.
Related Concept Videos
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...

