Determination of apple juice authenticity using gas chromatography-mass spectrometry, volt-ampere and new
Oksana V Bocharova1, Sentyabrina P Reshta1, Maiia Y Bocharova2
1Odessa National Academy of Food Technologies, Odessa, Ukraine.
Background:
Organoleptic properties and positive health effect on consumers both justify the importance of determining apple juice authenticity with respect to retail and wholesale trade networks worldwide.
Results:
Adulteration of apple juice through dilution with water, as well as with ascorbic acid, has been determined. It has been demonstrated that polarization curves of a platinum electrode in apple juice are useful for undeclared antioxidant determination, as a result of the movement of the polarization curve to the left, by 200 mV, when ascorbic acid was added. A difference between the equivalent electrical conductivity of suspended solids of undiluted and diluted (1:1) juices has been substantiated as a new quantitative criterion for determining adulteration through dilution. The criterion values range from 0.030 to 0.034 S m-1 for juices of different apple varieties. Gas chromatography-mass spectrometry results have shown the presence of (E)-2-hexenal and n-hexanal in all juices tested obtained from different apple varieties.
Conclusion:
A new conductometric method for the determination of diluted apple juices has been substantiated. It has been established that the volt-ampere method is useful for the investigation of undeclared ascorbic acid. © 2018 Society of Chemical Industry.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...