Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study.

Yingxuan Chen1, Fang-Fang Yin1,2,3, Yawei Zhang2

  • 1Medical Physics Graduate Program, Duke University, 2424 Erwin Road Suite 101, Durham, NC 27705, United States of America.

Summary

A new method called Prior Contour based Total Variation (PCTV) enhances edge information in Cone Beam CT (CBCT) reconstruction. PCTV improves image quality and accuracy in low-dose scenarios.

Related Concept Videos

What is Variation?01:14

What is Variation?

Apart from the measures of central tendency, distribution, outliers, and the changing characteristics of data with time, an important characteristic of any data set is its variation or spread. In some data sets, the data values are concentrated closely near the mean; in others, the data values are more widely spread out from the mean.
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
18.7K
Topographic Surveying and Contours01:29

Topographic Surveying and Contours

Topographic surveying is critical for documenting the Earth's surface, focusing on capturing elevations, slopes, and natural and man-made features. It is essential in construction planning, water resource management, and land-use analysis. The primary outcome of such surveys is a topographic map, which uses contour lines to visually represent the shape and slope of the terrain, providing valuable insights into the landscape's characteristics.Contour lines are fundamental to understanding the...
1.0K
Bioavailability Study Design: Single Versus Multiple Dose Studies01:11

Bioavailability Study Design: Single Versus Multiple Dose Studies

Bioavailability studies are essential for understanding how a drug is absorbed, distributed, metabolized, and excreted in the body. These studies assess the extent and rate at which the active pharmaceutical agent becomes available at the site of action. The design of bioavailability studies can involve single-dose or multiple-dose regimens, each with distinct advantages and limitations.Single-dose studies are the preferred approach due to their simplicity and reduced drug exposure for...
251
Conservative Site-specific Recombination and Phase Variation02:53

Conservative Site-specific Recombination and Phase Variation

Because the DNA segments are cut and reorganized in a direction-specific manner, site-specific recombination has emerged as an efficient genetic engineering technique. Flippase and Cyclization recombinases or Flp and Cre, respectively, are two members of the tyrosine recombinase family derived from bacteriophages, that are used to mediate site-specific DNA insertions, deletions, and targeted expression of proteins in mammalian cell lines.
The recognition sites for Cre recombinase called LoxP...
6.9K
Variation01:19

Variation

An important characteristic of any set of data is the variation in the data. In some data sets, the data values are concentrated closely near the mean; in other data sets, the data values are more widely spread out from the mean. The most common measure of variation, or spread, is the standard deviation, which is the square root of variance.
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
8.1K
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant01:25

Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant

In patients with renal disease, dosage adjustments are necessary to maintain therapeutic plasma drug concentrations and prevent toxicity or subtherapeutic exposure. Renal impairment alters drug pharmacokinetics, especially in conditions like uremia, where changes such as prolonged elimination half-life and altered apparent volume of distribution can significantly affect drug disposition. These changes require careful modification of the dosing regimen to achieve the desired clinical...
231