Related Experiment Video
Updated: Feb 12, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to
Dianning He1,2, Lisheng Xu1,3, Wei Qian1,4
1Sino-Dutch Biomedical and Information Engineering School, Northeastern University, Shenyang, China.
Abstract:
Due to large inter- and intra-patient variabilities of arterial input functions (AIFs), accurately modeling and using patient-specific AIF are very important for quantitative analysis of dynamic contrast enhanced MRI. Computer simulations were performed to evaluate and compare nine population AIF models with the Parker AIF used as 'gold standard'. The Parker AIF was calculated with a temporal resolution of 1.5 s, and then the other nine AIF models were used to fit the Parker AIF. A total of 100 randomly generated volume transfer constants (Ktrans) and distribution volumes (ve) were used to calculate the contrast agent concentration curves based on the Parker AIF and the extended Tofts model with blood plasma volume (vp) = 0.0, 0.01, 0.05 and 0.10. Subsequently, nine AIF models were used to fit these curves to extract physiological parameters (Ktrans, ve and vp). The agreements between generated and extracted Ktrans and ve values were evaluated using Bland-Altman analysis. The effects of the second pass of the Parker AIF model with and without adding Rician noise on extracted physiological parameters were evaluated by 1000 simulations using one of the nine mathematical AIF models closest to the Parker model with the smallest number of parameters. The results demonstrated that a six-parameter linear function plus bi-exponential function AIF model was almost equivalent to the Parker AIF and that the corresponding generated and extracted Ktrans and ve were in excellent agreements. The effects of the second pass of contrast agent circulation were small on extracted physiological parameters using the extended Tofts model, unless noise was added with signal to noise ratio less than 10 dB.
More Related Videos
Related Concept Videos
Mathematical Modeling: Problem Solving
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
The Quantum-Mechanical Model of an Atom
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Molecular Models
Typical Model Studies

