Variability of CT Airways Measurements in COPD Patients Between Morning and Afternoon: Comparisons to Variability of
Maxime Hackx1, Elodie Gyssels1, Tiago Severo Garcia1
1Department of Radiology, Hôpital Erasme, Université libre de Bruxelles, 808 Route de Lennik, 1070.
Rationale And Objectives:
Computed tomography (CT) airways measurements can be used as surrogates to spirometric measurements for assessing bronchodilation in a particular patient with chronic obstructive pulmonary disease. Although spirometric measurements show variations within the opening hours of a hospital department, we aimed to compare the variability of CT airways measurements between morning and afternoon in patients with chronic obstructive pulmonary disease to that of spirometric measurements.
Materials And Methods:
Twenty patients had pulmonary function tests and CT around 8 am and 4 pm. Luminal area (LA) and wall thickness (WT) of third and fourth generation airways were measured twice by three readers. The percentage of airway area occupied by the wall (WA%) and the square root of wall area at an internal perimeter of 10 mm (√WAPi10) were calculated. The effects of examination time, reader, and measurement session on CT airways measurements were assessed, and the variability of these measurements was compared to that of spirometric measurements.
Results:
Variability of LA3rd and LA4th was greater than that of spirometric measurements (P values ranging from <.001 to .033). There was no examination time effect on √WAPi10, WT3rd, LA4th, or WA%4th (P values ranging from .102 to .712). There was a reader effect on all CT airways measurements (P values ranging from <.001 to .028), except in WT3rd (P> .999). There was no effect of measurement session on any CT airway measurement (P values ranging from .535 to >.999).
Conclusion:
As the variability of LA3rd and LA4th is greater than that of spirometric measurements, clinical studies should include cohorts with larger numbers of patients when considering LA than when considering spirometric measurements as end points.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Graphs of Equations in Two Variables
Variables Affecting Phosphorescence and Fluorescence
Work and Energy for Variable Forces
Systems of Linear Equations in Two Variables