Related Experiment Video
Updated: Feb 12, 2026

Quantitating Iron Transport Across the Mouse Placenta In Vivo Using Nonradioactive Iron Isotopes
Published on: May 10, 2022
Assessment of MR-based R2* and quantitative susceptibility mapping for the quantification of liver iron concentration
Gregory Simchick1,2, Zhi Liu3, Tamas Nagy4
1Physics and Astronomy, University of Georgia, Athens, Georgia.
Purpose:
To assess the feasibility of quantifying liver iron concentration (LIC) using R2* and quantitative susceptibility mapping (QSM) at a high field strength of 7 Tesla (T).
Methods:
Five different concentrations of Fe-dextran were injected into 12 mice to produce various degrees of liver iron overload. After mice were sacrificed, blood and liver samples were harvested. Ferritin enzyme-linked immunosorbent assay (ELISA) and inductively coupled plasma mass spectrometry were performed to quantify serum ferritin concentration and LIC. Multiecho gradient echo MRI was conducted to estimate R2* and the magnetic susceptibility of each liver sample through complex nonlinear least squares fitting and a morphology enabled dipole inversion method, respectively.
Results:
Average estimates of serum ferritin concentration, LIC, R2*, and susceptibility all show good linear correlations with injected Fe-dextran concentration; however, the standard deviations in the estimates of R2* and susceptibility increase with injected Fe-dextran concentration. Both R2* and susceptibility measurements also show good linear correlations with LIC (R2 = 0.78 and R2 = 0.91, respectively), and a susceptibility-to-LIC conversion factor of 0.829 ppm/(mg/g wet) is derived.
Conclusion:
The feasibility of quantifying LIC using MR-based R2* and QSM at a high field strength of 7T is demonstrated. Susceptibility quantification, which is an intrinsic property of tissues and benefits from being field-strength independent, is more robust than R2* quantification in this ex vivo study. A susceptibility-to-LIC conversion factor is presented that agrees relatively well with previously published QSM derived results obtained at 1.5T and 3T.
More Related Videos
Related Concept Videos
Pharmacodynamic Models: Linear Concentration–Effect Model
Pharmacodynamic Models: Logarithmic Concentration–Effect Model
Pharmacodynamic Models: Emax Drug–Concentration Effect Model
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Concentration Cells
Consider the following voltaic cell:
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test