Related Experiment Video
Updated: Feb 12, 2026

MRI-guided Focused Ultrasound Thalamotomy for Patients with Medically-refractory Essential Tremor
Published on: December 13, 2017
Prospective Tractography-Based Targeting for Improved Safety of Focused Ultrasound Thalamotomy
Vibhor Krishna1, Francesco Sammartino1, Punit Agrawal1
1Center for Neuromodulation, The Ohio State University, Columbus, Ohio.
Background:
Focused ultrasound thalamotomy (FUS-T) was recently approved for the treatment of refractory essential tremor (ET). Despite its noninvasive approach, FUS-T reinitiated concerns about the adverse effects and long-term efficacy after lesioning.
Objective:
To prospectively assess the outcomes of FUS-T in 10 ET patients using tractography-based targeting of the ventral intermediate nucleus (VIM).
Methods:
VIM was identified at the intercommissural plane based on its neighboring tracts: the pyramidal tract and medial lemniscus. FUS-T was performed at the center of tractography-defined VIM. Tremor outcomes, at baseline and 3 mo, were assessed independently by the Tremor Research Group. We analyzed targeting coordinates, clinical outcomes, and adverse events. The FUS-T lesion location was analyzed in relation to unbiased thalamic parcellation using probabilisitic tractography. Quantitative diffusion-weighted imaging changes were also studied in fiber tracts of interest.
Results:
The tractography coordinates were more anterior than the standard. Intraoperatively, therapeutic sonications at the tractography target improved tremor (>50% improvement) without motor or sensory side effects. Sustained improvement in tremor was observed at 3 mo (tremor score: 18.3 ± 6.9 vs 8.1 ± 4.4, P = .001). No motor weakness and sensory deficits after FUS-T were observed during 6-mo follow-up. Ataxia was observed in 3 patients. FUS-T lesions overlapped with the VIM parcellated with probablisitic tractography. Significant microstructural changes were observed in the white matter connecting VIM with cerebellum and motor cortex.
Conclusion:
This is the first report of prospective VIM targeting with tractography for FUS-T. These results suggest that tractography-guided targeting is safe and has satisfactory short-term clinical outcomes.
More Related Videos
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Survey Safety
Household Wiring And Electrical Safety
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Coping Strategies: Problem Focused
For example, consider a student who struggles to understand their...
Focusing of Light in the Eye
Improving Translational Accuracy