Preparation of Tunable Microchips to Visualize Native Protein Complexes for Single-Particle Electron Microscopy

Brian L Gilmore1, A Cameron Varano1,2, William Dearnaley1

  • 1Virginia Tech Carilion Research Institute, Roanoke, VA, USA.

Summary

Single-particle electron microscopy (EM) advances with new methods for protein assembly studies. Combining lipid monolayer purification and silicon nitride microchips offers a flexible, tunable approach for researchers.

Related Concept Videos

Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
7.3K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.9K
Protein Complex Assembly02:41

Protein Complex Assembly

Proteins can form homomeric complexes with another unit of the same protein or heteromeric complexes with different types.  Most protein complexes self-assemble spontaneously via ordered pathways, while some proteins need assembly factors that guide their proper assembly. Despite the crowded intracellular environment, proteins usually interact with their correct partners and form functional complexes.
Many viruses self-assemble into a fully functional unit using the infected host cell to...
16.9K
Protein Complexes with Interchangeable Parts01:57

Protein Complexes with Interchangeable Parts

Groups of proteins may form a complex where each protein in this complex has a different role in the overall execution of the complex’s function. Often some of the proteins in the complex can be replaced by a closely related variant to give a complex that contains many of the same components yet is functionally distinct.
The SCF ubiquitin ligase is a protein complex of five individual proteins. This complex attaches ubiquitin to other target proteins to mark them for degradation. In order...
3.0K
Electron Transport Chain: Complex I and II01:46

Electron Transport Chain: Complex I and II

The mitochondrial electron transport chain (ETC) is the main energy generation system in the eukaryotic cells. However, mitochondria also produce cytotoxic reactive oxygen species (ROS) due to the large electron flow during oxidative phosphorylation. While Complex I is one of the primary sources of superoxide radicals, ROS production by Complex II is uncommon and may only be observed in cancer cells with mutated complexes.
ROS generation is regulated and maintained at moderate levels necessary...
19.1K
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
15.5K