Fixed angle plate fixation of comminuted patellar fractures
Tyler B Moore1, Bharat R Sampathi2, David P Zamorano3
1Ashley Regional Medical Center, Vernal, Utah, USA.
Introduction:
Comminuted patella fractures are uncommon and difficult fractures to manage. Multiple treatment modalities have been suggested, with little clinical data to support practice. Recent biomechanical and technical investigations have described successful plate fixation of comminuted patella fractures. The purpose of this study was to evaluate radiographic, clinical and functional outcome of comminuted patella fractures treated with a fixed angle locking plates. We believe stable fixation, which results in successful fracture union and functional recovery, can be achieved with this technique.
Materials And Methods:
A retrospective review was performed at a single regional academic Level 1 trauma hospital. All comminuted patella fractures treated with a fixed angle locking plate (AO/OTA 34C2 and C3) over a six-year period were evaluated. Thirty-six patients were identified. Average length of follow up was 154 weeks (range 12-297 weeks). Twenty patients were available for functional outcome scoring. Primary outcome measures were: Knee Outcome Score (KOS), Lower Extremity Functional Scale (LES) and goniometer measured knee range of motion. Secondary outcomes evaluated the need for additional screw or cerclage fixation, reoperation for any reason, bothersome hardware, infection and nonunion.
Results:
Average KOS = 57.2 (20-74), average LES = 58.9 (15-80). Median extension = 0° (full extension), median flexion = 130°. Supplemental screws were used in 17/36 cases; cerclage used in 2/36 cases. Hardware irritation was noted in 4/20 patients, no patient requested elective hardware removal, one patient had failure of fixation and no nonunions were identified.
Conclusion:
Fixed angle plate stabilization of comminuted patella fractures is a viable technique for fracture fixation. Good to excellent return of knee function and low complication rates, including need for hardware removal, can be expected.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
06:59Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
Related Concept Videos
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Fixed Action Patterns
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Fixing Double-strand Breaks
Angle of Twist: Problem Solving