25 years of quinacrine sterilization experience in Chile: review of 2,592 cases
1University of Chile, Sótero Del Río Hospital, Santiago, Chile.
Objectives:
To assess short-term side effects, long-term risks and efficacy of quinacrine sterilization (QS) in Chile.
Methods:
Review experience of 2,592 cases sterilized with 2 or 3 transcervical insertions of 252 mg quinacrine as pellets since 1977; review the Chilean pre-clinical experience and epidemiological studies on cervical, endometrial and other cancers.
Results:
Among 2,592 women who underwent QS, the total number of pregnancies was 119 (4.6%); 59 (49.5%) were carried to term with no birth defects related to QS. Nine cases were ectopic pregnancies. The ectopic pregnancy risk per 1,000 woman-years was 0.41, similar to that for surgical sterilization. The cumulative life-table pregnancy rates per 100 women at 10 years varied from 5.2 to 6.9. Mild and transient side effects were reported in 13.5% of quinacrine intrauterine insertions and pelvic inflammatory disease was diagnosed in 4 cases (0.15%). Long-term follow-up of quinacrine-sterilized patients shows no increased risk of cervical, endometrial or other cancer.
Conclusions:
QS efficacy at 10 years is comparable to widely accepted tubal clip and single point bipolar electrocoagulation laparoscopic procedures. QS has a low risk of serious, immediate side effects. No long-term risks have been identified after 25 years of use.
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
What is an Experiment?