Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
848
Longitudinal Evaluation of Bone-Anchored Hearing Aid Implant Stability Using the Advanced System for Implant
Lindsey Westover1, Gary Faulkner2, William Hodgetts3
1Department of Mechanical Engineering, University of Alberta.
Summary
The Advanced System for Implant Stability Testing (ASIST) shows promise for evaluating bone-anchored hearing aid implant stability over time. Initial stability may vary by surgeon and implant type, with changes observed during the first year post-surgery.
Area of Science:
- Biomedical Engineering
- Audiology
- Orthopedic Surgery
Background:
- Bone-anchored hearing aids (BAHA) require stable osseointegration for optimal function.
- Assessing implant stability is crucial for predicting long-term success and preventing complications.
- Existing methods for measuring implant stability may lack objectivity or longitudinal tracking capabilities.
Purpose of the Study:
- To clinically evaluate the Advanced System for Implant Stability Testing (ASIST) for assessing implant stability in BAHA patients.
- To analyze longitudinal changes in implant interface stability during the first year after surgery.
- To explore correlations between initial implant stability and clinical factors.
Main Methods:
- ASIST measurements (ASIST Stability Coefficient - ASC) were collected from 39 BAHA patients.
- Data collection occurred at surgery and at multiple time points up to 12 months post-surgery.
- Correlations were examined between ASC values and surgeon, patient age, and implant type.
Main Results:
- ASC values ranged from 11.9 to 137.0 (mean ± SD: 31.9 ± 18.0).
- A slight decrease in ASC was observed up to 3 months, followed by an increase by 1 year.
- Significant differences in initial stability were noted between operating surgeons (p<0.05), with a trend for implant types.
Conclusions:
- ASIST demonstrates promising results for the longitudinal evaluation of bone-implant interface integrity in a clinical setting.
- The system allows for objective, patient-specific comparisons of interface properties, distinguishing it from other measurement systems.
- ASIST may aid in identifying factors influencing initial implant stability in BAHA procedures.
Related Concept Videos
Nuclear Stability
23.4K
Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together...
To hold positively charged protons together...
23.4K
RNA Stability
35.8K
Intact DNA strands can be found in fossils, while scientists sometimes struggle to keep RNA intact under laboratory conditions. The structural variations between RNA and DNA underlie the differences in their stability and longevity. Because DNA is double-stranded, it is inherently more stable. The single-stranded structure of RNA is less stable but also more flexible and can form weak internal bonds. Additionally, most RNAs in the cell are relatively short, while DNA can be up to 250 million...
35.8K
Stability
425
The time response of a linear time-invariant (LTI) system can be divided into transient and steady-state responses. The transient response represents the system's initial reaction to a change in input and diminishes to zero over time. In contrast, the steady-state response is the behavior that persists after the transient effects have faded.
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
425
Stability of structures
532
In mechanical engineering, the stability of systems under various forces is critical for designing durable and efficient structures. One fundamental way to explore these concepts is by analyzing systems like two rods connected at a pivot point, O, with a torsional spring of spring constant k at the pivot point. This system is similar in appearance to a scissor jack used to change tires on a car. In this case, the arms of the linkage (equivalent to the rods in this system) are entirely vertical,...
532
Pole and System Stability
997
The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
997
Multimachine Stability
584
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
584