Ultrasonic Fatigue Testing in the Tension-Compression Mode
Published on: March 7, 2018
In Vitro Fatigue and Fracture Testing of Implant-Supported Anterior Ceramic Crowns
Purpose:
To evaluate the fatigue and fracture resistance of anterior implant-supported and tooth-supported crowns made of different monolithic ceramics.
Materials And Methods:
Anterior crowns were fabricated of lithium disilicate or one of two zirconia ceramics and were tested as tooth-supported (reference) or as implant-supported crowns with chairside or labside (screw channel) procedures. After thermocycling and mechanical loading (TCML), crowns were loaded to fracture.
Results:
All crowns survived TCML. Implant-supported crowns (chairside and labside) showed higher fracture values than tooth-supported crowns. Fracture resistance was comparable or higher for zirconia than for lithium disilicate crowns.
Conclusion:
Implant-supported ceramic crowns may withstand clinical anterior loading forces.