Altered Spatial Resolution of Scanning Electrochemical Microscopy Induced by Multifunctional Dual-Barrel

Lisa I Stephens1, Janine Mauzeroll1

  • 1Laboratory for Electrochemical Reactive Imaging and Detection of Biological Systems, Department of Chemistry , McGill University , Montreal , Quebec H3A 0B8 , Canada.

Related Concept Videos

What is an Electrochemical Gradient?01:26

What is an Electrochemical Gradient?

Adenosine triphosphate, or ATP, is considered the primary energy source in cells. However, energy can also be stored in the electrochemical gradient of an ion across the plasma membrane, which is determined by two factors: its chemical and electrical gradients.
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
128.4K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.6K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.6K
Alterations in Respiration II01:30

Alterations in Respiration II

There are numerous types of normal and abnormal respiration. Based on ventilatory movements, breathing patterns are classified as regular, deep, or shallow. Examples include Biot's breathing, Cheyne-Stokes respiration, Kussmaul's breathing, hyperventilation, and hypoventilation. Each pattern is clinically significant and aids in evaluating patients.
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
1.9K
Leaky Scanning02:28

Leaky Scanning

During most eukaryotic translation processes, the small 40S ribosome subunit scans an mRNA from its 5' end until it encounters the first start AUG codon. The large 60S ribosomal subunit then joins the smaller one to initiate protein synthesis. The location of the translation initiation is largely determined by the nucleotides near the start codon as there may be multiple translation initiation sites present on the mRNA.  Marilyn Kozak discovered that the sequence RCCAUGG (where R...
5.7K
Altered States of Awareness01:06

Altered States of Awareness

Altered states of consciousness represent significant deviations from one's normal mental state. These deviations can range from subtle changes in awareness to profound transformations in perception, thought processes, and sensory experiences. Altered states of consciousness can be triggered by various factors, including drug use, meditation, hypnosis, illness, or even intense fatigue.
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
1.2K