Related Experiment Video
Updated: Feb 10, 2026

Lower-Limb Biomechanical Characteristics Associated with Unplanned Gait Termination Under Different Walking Speeds
Published on: August 25, 2020
Biomechanical Characteristics of Biplane Multiplanar Tension-Side Fixation for Lapidus Fusion
Paul Dayton1, Daniel J Hatch2, Robert D Santrock3
1Assistant Professor, College of Podiatric Medicine and Surgery, Des Moines University, Des Moines, IA.
Abstract:
Although plating on the plantar, tension-side of the metatarsocuneiform joint provides an inherent biomechanical advantage for Lapidus arthrodesis, it has not been widely adopted owing to the morbidity associated with plantar application. To overcome these limitations, a modification to 90-90 locked biplanar plating was developed to provide the biomechanical advantages of multiplanar fixation and tension-side fixation, allowing application through a conventional incision. We tested the hypothesis that biplanar plating with tension-side fixation (low-profile straight dorsal plate and anatomic medial-plantar plate) would demonstrate improved mechanical stability compared with a previously tested 90-90 biplanar construct (small straight plate dorsally and medially) under cyclic loading. Both constructs were tested in static load to failure (3 pairs) and cyclic loading (10 pairs) with plantar cantilever bending using surrogate anatomic bone models. With static ultimate failure, the biplanar plate construct with tension-side fixation failed at a significantly greater failure load than did the straight biplanar plate construct (247.3 ± 18.4 N versus 210.9 ± 10.4 N; p = .04). With cyclic failure testing, the biplanar plate construct with tension-side fixation endured a significantly greater number of cycles (206,738 ± 49,103 versus 101,780 ± 43,273; p < .001) and a significantly greater dynamic failure load (207.5 ± 24.3 N versus 162.5 ± 20.6 N; p < .001) compared with the straight biplanar plate construct. These results have demonstrated that under simulated static and cyclic Lapidus arthrodesis loading, biplanar plating with tension-side fixation provides superior strength compared with the straight biplanar construct. Thus, this construct shows promise for clinical application as a practical approach to tension-side fixation and an early return to weightbearing after Lapidus fusion.
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Tension
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Characteristics of Life
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Surface Tension of Fluid
Surface tension varies...

