Related Experiment Video
Updated: Jul 30, 2026

An Anatomical Study of Nerves at Risk During Minimally Invasive Hallux Valgus Surgery
Published on: February 17, 2018
Instrumented correction of metatarsus adductus with hallux valgus - A multicenter radiographic assessment
Jody Peter McAleer1, Paul Dayton2, Mindi Dayton2
1Jefferson City Medical Group, Department of Podiatry, Jefferson City, MO 65109, USA.
Abstract:
Failure to address metatarsus adductus (MTA) with coexisting hallux valgus (HV) has resulted in mixed outcomes and increased deformity recurrence. The purpose of this study was to investigate early radiographic and clinical outcomes of a novel instrumented 2nd and 3rd TMT corrective arthrodesis combined with instrumented triplanar 1st TMT arthrodesis with early weightbearing. Radiographs and medical records from subjects undergoing this surgical approach were retrospectively reviewed. Forty-three subjects (N = 43 feet) with a mean ± SD age of 41.6 ± 14.2 (range 15 to 62) years were treated at four institutions with a mean ± SD follow-up time of 17.7 ± 10.6 (range 11.5 to 51.0) months. Radiographic parameters demonstrated improvements in the mean ± SD Sgarlato's angle (26.3 ± 5.7 to 10.2 ± 3.8 degrees), baseline 'True Intermetatarsal Angle' (23.2 ± 6.6 degrees) to measured Intermetatarsal Angle at final follow-up (3.7 ± 2.4 degrees), Hallux Valgus Angle (32.3 ± 8.4 to 7.2 ± 6.6 degrees), Tibial Sesamoid Position (5.0 ± 1.5 to 1.3 ± 1.1) and Osseous Foot Width (97.8 ± 7.0 to 86.8 ± 7.5 mm). The novel baseline Plumbline measurement was 93.0 % positive in the study cohort and converted to a negative reading following MTA correction in 90.7 % of subjects. All (N = 43) feet studied achieved stable arthrodesis at the time of final clinical and radiographic assessment. One patient required hardware removal. Radiographic outcomes of an instrumented triplanar correction and multi-planar locking plate fixation were promising with correction of the MTA and HV deformities and favorable healing noted.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Mass Analyzers: Overview
Atomic Emission Spectroscopy: Instrumentation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

