Related Experiment Video
Updated: Feb 10, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Detector-specific correction factors in radiosurgery beams and their impact on dose distribution calculations
Olivia A García-Garduño1, Manuel A Rodríguez-Ávila2, José M Lárraga-Gutiérrez1
1Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía, México City, México.
Abstract:
Silicon-diode-based detectors are commonly used for the dosimetry of small radiotherapy beams due to their relatively small volumes and high sensitivity to ionizing radiation. Nevertheless, silicon-diode-based detectors tend to over-respond in small fields because of their high density relative to water. For that reason, detector-specific beam correction factors ([Formula: see text]) have been recommended not only to correct the total scatter factors but also to correct the tissue maximum and off-axis ratios. However, the application of [Formula: see text] to in-depth and off-axis locations has not been studied. The goal of this work is to address the impact of the correction factors on the calculated dose distribution in static non-conventional photon beams (specifically, in stereotactic radiosurgery with circular collimators). To achieve this goal, the total scatter factors, tissue maximum, and off-axis ratios were measured with a stereotactic field diode for 4.0-, 10.0-, and 20.0-mm circular collimators. The irradiation was performed with a Novalis® linear accelerator using a 6-MV photon beam. The detector-specific correction factors were calculated and applied to the experimental dosimetry data for in-depth and off-axis locations. The corrected and uncorrected dosimetry data were used to commission a treatment planning system for radiosurgery planning. Various plans were calculated with simulated lesions using the uncorrected and corrected dosimetry. The resulting dose calculations were compared using the gamma index test with several criteria. The results of this work presented important conclusions for the use of detector-specific beam correction factors ([Formula: see text] in a treatment planning system. The use of [Formula: see text] for total scatter factors has an important impact on monitor unit calculation. On the contrary, the use of [Formula: see text] for tissue-maximum and off-axis ratios has not an important impact on the dose distribution calculation by the treatment planning system. This conclusion is only valid for the combination of treatment planning system, detector, and correction factors used in this work; however, this technique can be applied to other treatment planning systems, detectors, and correction factors.
Related Concept Videos
Power Factor Correction
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
Factors Affecting Drug Distribution: Miscellaneous Factors
Age plays a significant role due to differences in body composition among different age groups. Infants, for instance, have a higher proportion of total body water and lower albumin levels, a protein that binds drugs in the bloodstream. This unique composition in infants enhances the...
Distribution of Stresses in a Narrow Rectangular Beam
Dose-Response Relationship: Selectivity and Specificity
Factors Affecting Drug Distribution: Tissue Permeability
Small molecules with a molecular weight below 500 to 600 Daltons can easily pass through the capillary membrane, gaining access to different tissues. Larger...

