Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Foveal Avascular Zone Area Analysis in Macular Hole Before and After Surgery Using Optical Coherence Tomography
Background And Objective:
To analyze the foveal avascular zone (FAZ) area in superficial and deep retinal layers in patients with macular hole (MH) before and after surgery.
Patients And Methods:
The authors studied 14 patients with unilateral MH. They examined a 3 mm × 3 mm area at the fovea before and 6 months after surgery using spectral-domain optical coherence tomography angiography.
Results:
In eyes affected by MH, the mean preoperative superficial FAZ (0.45 ± 0.09 mm2) and deep FAZ (0.79 ± 0.39 mm2) were significantly larger than the postoperative superficial FAZ (0.25 ± 0.09 mm2) and deep FAZ (0.31 ± 0.12 mm2), respectively (P < .001). The mean preoperative superficial FAZ of the affected eyes was the same as that of control eyes (0.41 ± 0.10 mm2) (P = .23), but postoperative superficial FAZ was smaller than that of control eyes (P < .001). The mean preoperative deep FAZ was larger (0.48 ± 0.11 mm2) (P = .019), but mean postoperative deep FAZ was smaller than that of control eyes (P < .001).
Conclusions:
The authors revealed preoperative deep FAZ areas were more enlarged centrifugally than preoperative superficial FAZ in MH. Both postoperative superficial and deep FAZ showed more centripetal contraction than those of the preoperative period. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:329-335.].
Related Concept Videos
Hybrid Zones
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Transition Zone
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...