Related Experiment Video
Updated: Feb 10, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity
Macarena Silva1, Carolina Mendiguchía1, Carlos Moreno1
1Department of Analytical Chemistry, Faculty of Marine and Environmental Science, University of Cádiz, Puerto Real, Spain.
Abstract:
Simultaneous electromembrane extraction (EME) of six trace metal cations (Cu2+ , Zn2+ , Co2+ , Ni2+ , Pb2+ , Cd2+ ) from saline samples was investigated. CE with capacitively coupled contactless conductivity detection (C4 D) was used to determine the metals in acceptor solutions due to its excellent compatibility with the minute volumes of acceptor solutions. Bis(2-ethylhexyl)phosphate (DEHPA) was selected as a suitable nonselective modifier for EME transport of target metal cations. Both, the individual effect of each major inorganic cation (Na+ , K+ , Ca2+ , Mg2+ ) and their synergistic effect on EME of the trace metal cations were evaluated. In both cases, a decrease in extraction efficiency was observed when major inorganic cations were present in the sample. This effect was more significant for Ca2+ and Mg2+ . The system was optimized for simultaneous extractions of the six target metals from saline samples (50 mM Na+ , 5 mM Mg2+ , 1 mM K+ , and 1 mM Ca2+ ) and following EME conditions were applied. Organic phase consisted of 1-nonanol containing 1% (v/v) DEHPA, acceptor solution was 1 M acetic acid (HAc) and sample pH was adjusted to 5. Sample was stirred at 750 rpm and EMEs were carried out at extraction potential of 10 V for 20 min. The method presented a repeatability between 8 and 21.8% (n = 5), good linearity in 0.5-10 μM concentration range (R2 = 0.987-0.999) and LOD better than 2.6 nM. Applicability of the EME-CE-C4 D method to the analyses of metal cations in drinking water, seawater, and urine samples was also demonstrated.
More Related Videos
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
11:39Extraction of Aqueous Metabolites from Cultured Adherent Cells for Metabolomic Analysis by Capillary Electrophoresis-Mass Spectrometry
Published on: June 9, 2019
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Theory of Metallic Conduction
In this theory, Newton's second law of motion is used to determine the acceleration of an electron in the presence of an applied electric field. Then, its velocity is expressed via this acceleration.
An electron moves through the crystal, containing positive ions,...
Extraction: Effects of pH
Extraction: Advanced Methods
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...