Further Validation of a Rapid Screening Semiquantitative Thin-Layer Chromatographic Method for Marketed Antimalarial
Dorcas Osei-Safo1, Ibrahim Chikowe1,2, Jerry Joe Ebow Kingsley Harrison1
1Chemistry Department, School of Mathematical and Physical Sciences, College of Basic and Applied Sciences, University of Ghana, Accra, Ghana.
Abstract:
A recently developed semiquantitative thin-layer chromatographic (SQ-TLC) assay has been employed in postmarketing surveillance of antimalarial medicines used in Malawi prior to HPLC assay. Both methods gave analogous results in a significant majority of the samples, with a good correlation (r = 0.9012) for the active pharmaceutical ingredients of the dosage forms assayed. Artemether-containing medicines had the highest percentage (92.67%) of samples with comparable results for both assays. The lowest percentage (66.67%) was observed in artesunate-containing medicines. The SQ-TLC method was validated for specificity, accuracy, precision, linearity, and stability according to the International Conference on Harmonisation guidelines, with the results falling within acceptable limits. For specificity, retention factor values of the test samples and reference standards were comparable, while accuracy and precision of 91.1 ± 5.7% were obtained for all samples. The method was linear in the range 1.0-2.0 µg/spot with a correlation coefficient of r = 0.9783. Stability tests also fell within acceptable limits. In this study, we present the validation of the SQ-TLC method and propose its adoption as a rapid screening tool for field estimation of the quality of antimalarial and other essential medicines in Malawi and other parts of the developing world prior to a more accurate HPLC assay.
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Reliability and Validity
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Data Validation
Key parameters for method validation include: