Micro-computed Tomography Shaping Ability Assessment of the New Blue Thermal Treated Reciproc Instrument
Felipe Gonçalves Belladonna1, Marco Simões Carvalho1, Daniele Moreira Cavalcante1
1Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.
Introduction:
The present study aimed to assess canal preparation outcomes achieved by the new Reciproc Blue instrument using micro-computed tomography technology. M-Wire Reciproc was used as a reference instrument for comparison.
Methods:
Seven pair-matched mesial roots of mandibular molars presenting similar anatomic features of the canal (length, volume, surface area, and configuration) were selected after scanning procedures and assigned to 1 of the 2 groups according to the instrument used, M-Wire Reciproc and Reciproc Blue. After canal instrumentation, the specimens were rescanned, and the registered preoperative and postoperative datasets were examined to evaluate the percentages of removed dentin, untouched canal walls, and degree of canal transportation. Comparisons regarding the above outcomes between the 2 groups were done by using paired t test with the alpha-type set at 5%.
Results:
Root canals prepared with conventional M-Wire Reciproc or Reciproc Blue were found to present similar shaping properties with no significant differences in the tested parameters.
Conclusions:
M-Wire Reciproc and Blue Reciproc presented similar shaping outcomes.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
09:11Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
Published on: October 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Molecular Shape and Polarity
Factors Influencing Attraction IV: Reciprocity
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...