Related Experiment Video
Updated: Feb 9, 2026

08:48
Author Spotlight: Decoding Mitochondrial Aging
Published on: June 30, 2023
4.9K
Three dimensional live-cell STED microscopy at increased depth using a water immersion objective.
Jörn Heine1, Christian A Wurm1, Jan Keller-Findeisen2
1Abberior Instruments GmbH, Hans-Adolf-Krebs-Weg 1, 37077 Göttingen, Germany.
The Review of Scientific Instruments
|June 6, 2018
Summary
Water immersion objectives improve super-resolution microscopy for deep live-cell imaging. This approach corrects aberrations, enhancing axial resolution in stimulated emission depletion (STED) microscopy beyond oil objectives.
Area of Science:
- Biophysics
- Optical Microscopy
Background:
- Super-resolution microscopy, like stimulated emission depletion (STED), enables nanoscale imaging of living cells.
- High numerical aperture (NA) oil objectives are common for STED but suffer from spherical aberrations in aqueous media at depth.
Purpose of the Study:
- To overcome limitations of oil objectives in deep live-cell STED imaging.
- To enhance axial resolution in z- and 3D-STED microscopy at greater penetration depths.
Main Methods:
- Utilized a water immersion objective combined with a spatial light modulator for z-STED.
- Developed a compact system allowing objective switching and real-time STED point spread function (PSF) aberration correction.
- Theoretically and experimentally investigated the influence of NA on axial STED resolution.
Main Results:
- Demonstrated superior performance of water immersion objectives compared to oil objectives for deep live-cell STED imaging (5-180 μm).
- Successfully corrected for spherical aberrations caused by refractive index mismatch.
- Significantly improved axial resolution in z-STED measurements.
Conclusions:
- Water immersion objectives offer a viable solution for high-resolution deep live-cell STED microscopy.
- The developed system provides enhanced axial resolution and aberration correction capabilities.
- This advancement is crucial for studying cellular dynamics at nanometer scales within intact biological samples.
More Related Videos
Related Concept Videos
Two-Dimensional Microscopy in Microbiology
1.6K
Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...
1.6K
Three-Dimensional Microscopy in Microbiology
865
Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
865
Increasing Function
400
An increasing function exhibits a rise in output values as input values increase. This behavior is depicted graphically as a curve or line that slopes upward from left to right. Such a function satisfies the condition that if x1 < x2, then f(x1) < f(x2), indicating that the function values grow with increasing inputs. This concept is fundamental in understanding growth trends across various domains, such as population dynamics, financial investments, or resource consumption.The...
400
Dimensional Analysis
65.1K
Dimensional analysis, also known as the factor label method, is a versatile approach for mathematical operations. The main principle behind this approach is: the units of quantities must be subjected to the same mathematical operations as their associated numbers. This method can be applied to computations ranging from simple unit conversions to more complex and multi-step calculations involving several different quantities and their units.
Conversion Factors and Dimensional Analysis
The unit...
Conversion Factors and Dimensional Analysis
The unit...
65.1K
States of Water
57.1K
Water exists in any one of the three classical states: solid (ice), liquid (water), and gas (steam or water vapor). The state of water depends on i) the intermolecular forces that draw molecules together and ii) the kinetic energy that leads to movements that pull them apart.
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
57.1K
Velocity of an Object
207
Understanding how an object moves along a path requires distinguishing between motion over a time span and motion at a precise moment. A useful example is a vehicle traveling along a straight and level path, where its position at any given time is known. The initial step in analyzing this motion is to measure how far the vehicle travels over a fixed time period. This measurement, called average velocity, is computed by dividing the total change in position by the duration over which the change...
207

