Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
An automated planning strategy for near real-time adaptive proton therapy in prostate cancer
Thyrza Jagt1, Sebastiaan Breedveld1, Rens van Haveren1
1Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Abstract:
Proton therapy plans are very sensitive to anatomical changes such as density changes along the pencil-beam paths and changes in organ shape and location. Previously, we developed a restoration method which compensates for density changes along the pencil-beam paths but which is unable to adapt for anatomical changes. This study's purpose is to develop and evaluate an automated method for adaptation of IMPT plans in near real-time to the anatomy of the day. We developed an automated treatment plan adaptation method using (1) a restoration of spot positions (Bragg peaks) by adapting the energies to the new water equivalent path lengths; and (2) a spot addition to fully cover the target of the day, followed by a fast reference point method optimization of the spot weights resulting in a Pareto optimal plan for the daily anatomy. The method was developed and evaluated using 8-10 repeat CT scans of 11 prostate cancer patients, prescribing 55 Gy(RBE) (seminal vesicles and lymph nodes) with a boost to 74 Gy(RBE) (prostate). Applying the automated adaptation method resulted in a clinically acceptable target coverage (V 95% [Formula: see text] 98% and V 107% [Formula: see text] 2%) for 96% of the scans after a single iteration of adding 2500 spots. The other scans obtained target coverages with V 95% [Formula: see text] 98% and 2 < V 107% [Formula: see text] 5%. When using two spot-addition iterations, all scans obtained clinically acceptable results. Compared to the restoration method the adaptation lowered the mean dose to rectum and bladder with median values of 6.2 Gy(RBE) and 4.7 Gy(RBE) respectively. The largest improvements were obtained for V 45Gy(RBE) for both rectum and bladder, with median differences of 10.3%-point and 10.8%-point respectively, and maximum differences up to 22%-point. The two adaptation steps took on average 7.3 s and 1.7 min respectively. No user interaction was needed, making this fast and fully automated method a first step towards online adaptive proton therapy.
Related Concept Videos
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
Adaptive Mechanisms in Cancer Cells
Some of the advantages that cancer cells have on normal cells include - enhanced ability to divide without terminally differentiating, induce new blood vessel formation,...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Planning Nursing Care I