Related Experiment Video
Updated: Feb 9, 2026

Exergaming in Older People Living with HIV Improves Balance, Mobility and Ameliorates Some Aspects of Frailty
Published on: October 6, 2016
Computed tomography quantification of emphysema in people living with HIV and uninfected controls
Andreas Ronit1, Thomas Kristensen2, Vilde S Hoseth1
1Viro-immunology Research Unit, Dept of Infectious Diseases 8632, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Abstract:
People living with HIV (PLWH) may be more susceptible to the development of emphysema than uninfected individuals. We assessed prevalence and risk factors for emphysema in PLWH and uninfected controls. Spirometry and chest computed tomography scans were obtained in PLWH from the Copenhagen Comorbidity in HIV Infection (COCOMO) study and in uninfected controls from the Copenhagen General Population Study (CGPS) who were >40 years. Emphysema was quantified using a low attenuation area < -950 Hounsfield units (%LAA-950) and the 15th percentile density index (PD15) and assessed by semi-quantitative visual scales. Of 742 PLWH, 21.2% and 4.7% had emphysema according to the %LAA-950 threshold with cut-offs at 5% and 10%, respectively. Of 470 uninfected controls, these numbers were 24.3% (p=0.23) and 4.0% (p=0.68). HIV was not associated with emphysema (adjusted OR 1.25, 95% CI 0.68-2.36 for %LAA-950 >10%) by PD15 or by visually assessed emphysema. We found no interaction between HIV and cumulative smoking. Breathlessness and sputum production were more common in PLWH with emphysema, and emphysema seemed to be more prevalent in PLWH with airflow limitation. HIV was therefore not independently associated with emphysema, but the clinical impact of emphysema was greater in PLWH than in uninfected controls.
More Related Videos
13:08Visualizing Cell-to-cell Transfer of HIV using Fluorescent Clones of HIV and Live Confocal Microscopy
Published on: October 7, 2010
07:29Determination of Molecular Structures of HIV Envelope Glycoproteins using Cryo-Electron Tomography and Automated Sub-tomogram Averaging
Published on: December 1, 2011
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Design Example: Traverse Angle Computations
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Area Computation by the Alternative Coordinate Method
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...