Related Experiment Video
Updated: Feb 9, 2026

Detection of Phytophthora capsici in Irrigation Water using Loop-Mediated Isothermal Amplification
Published on: June 25, 2020
Evaluation of Apically Extruded Debris Using Positive and Negative Pressure Irrigation Systems in Association with
Marlos Barbosa-Ribeiro1, Rodrigo Arruda-Vasconcelos1, Fabio L Fabretti1
1Department of Restorative Dentistry, Division of Endodontics, Piracicaba Dental School, State UNICAMP - Universidade Estadual de Campinas, Piracicaba, SP, Brazil.
Abstract:
This study evaluated the amount of apically extruded debris after chemo-mechanical preparation (CMP) using positive and negative pressure irrigation systems [Conventional irrigation (CI) and EndoVac (EV)] in association with different irrigants [6% Sodium Hypochlorite (NaOCl), 2% Chlorhexidine gel + saline solution (CHXg + SS), 2% Chlorhexidine solution (CHXs) or Saline solution (SS)]. Eighty mandibular premolars with single root canals were selected and randomly assigned into 8 groups (n = 10) according to the irrigation system and the irrigant used during CMP: G1 (EV + NaOCl), G2 (EV + CHXg + SS), G3 (EV + CHXs), G4 (EV + SS), G5 (CI + NaOCl), G6 (CI + CHXg + SS), G7 (CI + CHXs) and G8 (CI + SS). Reciproc® R25 files (25/.08) were used during the CMP and the extruded debris from each tooth was collected in pre-weighted Eppendorf tubes and dried. The average weight of debris was assessed using a microbalance, and the data were statistically analyzed using ANOVA and the post hoc Tukey's test (a = 0.05). All groups were associated with debris extrusion. EV was the irrigation system with less extruded debris (p < 0.05). No differences were observed regarding the irrigant when EV was used. When CI was used, CHXg + SS were associated with lower debris extrusion (p < 0.05). It was concluded that no irrigation protocol succeeded in preventing debris extrusion. EV resulted in lower levels of debris extrusion than CI. The use of CHXg + SS resulted in lower debris extrusion.
More Related Videos
06:45Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
Related Concept Videos
Design Example: Design of an Irrigation Channel
Positive, Negative, and Zero Work
Positive and Negative Feedback Loops
Root Loci for Positive-Feedback Systems
The construction rules for the root locus in positive feedback systems are similar to those in...
Gram-negative Bacterial Protein Secretion Systems
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: