Related Experiment Video
Updated: Feb 8, 2026

A RAPID Method for Blood Processing to Increase the Yield of Plasma Peptide Levels in Human Blood
Published on: April 28, 2016
Sensitive and rapid determination of amantadine without derivatization in human plasma by LC-MS/MS for a
Abhaysingh Bhadoriya1, Shivprakash Rathnam1, Bhavesh Dasandi1
1Bioanalytical Department, Synchron Research Services Pvt. Ltd, 5th Floor, The Chambers, Sarkhej-Gandhinagar Highway, Bodakdev, Ahmedabad 380054, India.
Abstract:
A highly sensitive, rapid and rugged liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS) method was developed for reliable estimation of amantadine (AMD), an antiviral drug in human plasma. The analyte and internal standard (IS), amantadine-d6 (AMD-d6), were extracted from 200 µL plasma by solid phase extraction on Phenomenex Strata-X-C 33 µ cartridges. Chromatography was performed on Synergi™ Hydro-RP C18 (150 mm × 4.6 mm, 4 µm) analytical column using a mixture of acetonitrile and 10 mM ammonium formate, pH 3.0 (80:20, v/v) as the mobile phase. Detection and quantitation was done by multiple reaction monitoring in the positive ionization mode for AMD (m/z 152.1 → 135.1) and IS (m/z 158.0 → 141.1) on a triple quadrupole mass spectrometer. The assay was linear in the concentration range of 0.50-500 ng/mL with correlation coefficient (r2) ≥ 0.9969. The limit of detection of the method was 0.18 ng/mL. The intra-batch and inter-batch precisions were ≤ 5.42% and the accuracy varied from 98.47% to 105.72%. The extraction recovery of amantadine was precise and quantitative in the range of 97.89%-100.28%. IS-normalized matrix factors for amantadine varied from 0.981 to 1.012. The stability of AMD in whole blood and plasma was evaluated under different conditions. The developed method was successfully applied for a bioequivalence study with 100 mg of AMD in 32 healthy volunteers. The reproducibility of the assay was determined by reanalysis of 134 subject samples.
Related Concept Videos
Bioequivalence studies: Biowaivers
Bioequivalence: Overview
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Urine Studies II: Urine Culture and Sensitivity Test
Equivalence: In Vitro and In Vivo Bioequivalence

