Validation of method for analysing mechanics of unloader brace for medial knee osteoarthritis
Shannon R Neville1, Scott C E Brandon2, Marcus J Brown1
1Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada.
Abstract:
Unloader braces are one non-invasive treatment of knee osteoarthritis, which primarily function by applying an external abduction moment to the joint to reduce loads in the medial compartment of the knee. We developed a novel method using brace deflection to estimate the mechanical effect of valgus braces and validated this model using strain gauge instrumentation. Three subjects performed static and walking trials, in which the moment applied by an instrumented brace was calculated using the deflection and strain methods. The deflection method predicted average brace moments of 8.7 Nm across static trials; mean error between the deflection model predictions and the gold-standard strain gauge measurements was 0.32 Nm. Mean brace moment predictions throughout gait ranged from 7.1 to 8.7 Nm using the deflection model. Maximum differences (MAE) over the gait cycle in mean and peak brace moments between methods were 1.50 Nm (0.96) and 0.60 Nm (0.42). Our proposed method enables quantification of brace abduction moments without the use of custom instrumentation. While the deflection-based method is similar to that implemented by Schmalz et al. (2010), the proposed method isolates abduction deflection from the 3 DOF angular changes that occur within the brace. Though the model should be viewed with more caution during swing (MAE = 1.16 Nm), it was shown that the accuracy is influenced by the uncertainty in angle measurement due to cluster spacing. In conclusion, the results demonstrate that the deflection-based method developed can predict comparable brace moments to those of the previously established strain method.
Related Concept Videos
Reliability and Validity
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...