Objective:
Digitally designed titanium plates are commonly used for the reconstruction of craniofacial defects, although implant exposure (referred to as failure) is one of the major complications. Metal hypersensitivities have been suggested as possible causes of implant failure of orthopedic, intravascular, gynecological, and dental devices, yet there has been no consensus on the requirement for allergy screening before cranioplasty.
Methods:
In this study, the authors prospectively investigated the prevalence of metal hypersensitivity in patients for whom cranioplasty is planned and assess its relationship with titanium implant failure (exposure).
Results:
Based on records from 207 included patients, 39.61% of patients showed hypersensitivity to at least one kind of metal. Approximately one-quarter (25.12%) of patients had multiple metal allergies. Co, Cd, and Zn were the 3 most frequently identified metal hypersensitivities. No allergy to titanium was detected in this study. The overall incidence of cranioplasty implant failure was 5.31% (11 of 207). Patients showing hypersensitivities to more than 3 kinds of metal had higher risks of titanium plate exposure.
Conclusions:
Based on their findings, the authors suggest that routine allergy screening be performed before titanium plate cranioplasty. For patients with hypersensitivities to more than 3 metals, alternative materials, such as polyetheretherketone, should be considered for cranioplasty.
More Related Videos
07:28Imaging Cell Viability on Non-transparent Scaffolds — Using the Example of a Novel Knitted Titanium Implant
Published on: September 7, 2016
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Alkali Metals
Table 1: Properties of the alkali metals
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Association Areas of the Cortex
Prefrontal Association Area: This area is located in the frontal lobe and is involved in planning, decision-making, and moderating social behavior. It connects with primary motor areas,...