Related Experiment Video
Updated: Feb 8, 2026

Culture of Neurospheres Derived from the Neurogenic Niches in Adult Prairie Voles
Published on: June 10, 2020
Single pot bioconversion of prairie cordgrass into biohydrogen by thermophiles
Mohit Bibra1, Sudhir Kumar2, Jia Wang1
1Department of Chemical and Biological Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA.
Abstract:
The aim of the present work was to use a thermophilic consortium for H2 production using lignocellulosic biomass in a single pot. The thermophilic consortium, growing at 60 °C utilized both glucose and xylose, making it an ideal source of microbes capable of utilizing and fermenting both hexose and pentose sugars. The optimization of pH, temperature, and substrate concentration increased the H2 production from 1.07 mmol H2/g of prairie cordgrass (PCG) to 2.2 mmol H2/g PCG by using the thermophilic consortium. A sequential cultivation of a thermostable lignocellulolytic enzyme producing strain Geobacillus sp. strain WSUCF1 (aerobic) with the thermophilic consortium (anaerobic) further increased H2 production with PCG 3-fold (3.74 mmol H2/g PCG). A single pot sequential culturing of aerobic and anaerobic microbes can be sustainable and advantageous for industrial scale production of biofuels.
Related Concept Videos
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Angular Momentum: Single Particle
Single-pass Transmembrane Proteins
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...

