Related Experiment Video
Updated: Feb 8, 2026

Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
Published on: November 4, 2009
Development of mini-spectrophotometer for determination of plasma glucose
Natpasit Chaianantakul1, Kanchaporn Wutthi1, Nattanit Kamput1
1Department of Medical Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok 65000, Thailand.
Abstract:
This work demonstrates a novel compact spectrophotometer, "Mini-spectrophotometer", designed for plasma glucose detection. Unlike conventional spectrophotometer, a light source of the mini spectrophotometer is replaced by a light-emitting diode (LED), and a fabricated polymer-based microwell is used as a cuvette. To validate the downsizing spectrophotometer prototype, the efficiency and reliability for glucose determination are investigated. Using a certain light intensified from LED, the within-run precision of mini-spectrophotometer is found to be 3.9-8.4% while the between-run precision is 6.7-10.8%. The linearity for the quantification of glucose was up to 500 mg dL-1 and the recovery 99.1 ± 3.4% is obtained. The sensitive and selective detection of glucose has been observed; with limit of detection (LOD) of 13.5 mg dL-1 and limit of quantification (LOQ) of 46.2 mg dL-1, respectively. Hemoglobin and triglyceride at high concentration slightly interferes with the proposed instrument. From comparative studies, there are no significant differences between the glucose concentration measured by mini-spectrophotometer and Shimadzu (r2 = 0.9862) or CECIL spectrophotometer (r2 = 0.9853). Using Passing-Bablok regression analysis, the results obtained from mini-spectrophotometer are in close agreement with the two conventional spectrophotometers. Furthermore, using microwell, the sample volume and reagent used in the process can be reduced. The in-house developed mini-spectrophotometer is capable of detecting plasma glucose while maintaining a compact system, demonstrating the potential of high performance, cost-effective, and portable spectrophotometer for clinical chemistry analysis in small routine, research, and teaching medical laboratory technologist.
Related Concept Videos
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Glucose Transporters
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Glucose Absorption Into the Small Intestine
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Composition of Blood Plasma
Determining Order of Reaction

