Robust Methods for Automated Selection of Cardiac Signals After Blind Source Separation
IEEE Transactions on Bio-Medical Engineering
|July 12, 2018
Summary
New methods for selecting cardiac signals from noisy minimum-contact vital signs monitoring, like textile electrocardiogram (ECG), reliably identify heartbeats even with motion artifacts and arrhythmias.
Area of Science:
- Biomedical Engineering
- Signal Processing
- Wearable Health Technology
Background:
- Minimum-contact vital signs monitoring, including textile and capacitive electrocardiogram (ECG), offers advanced health monitoring capabilities.
- These novel techniques are susceptible to motion artifacts and signal instability, posing challenges for accurate data extraction.
- Spatio-temporal blind source separation (BSS) can process multichannel signals but faces permutation indeterminacy, requiring cardiac signal identification.
Purpose of the Study:
- To evaluate different concepts for resolving permutation indeterminacy in spatio-temporal BSS for vital signs monitoring.
- To compare novel automated component selection routines based on heartbeat detection against standard BSS component selection methods.
Main Methods:
- Applied spatio-temporal BSS to textile and capacitive ECG datasets from subjects performing motion protocols.
- Utilized the MIT-BIH Arrhythmia Database for evaluating performance on arrhythmia data.
- Compared heartbeat-detection-based selection routines with standard methods (higher-order moments, frequency-domain features) using heartbeat detection accuracy (ACC).
Main Results:
- Heartbeat-detection-based selection routines significantly outperformed standard selectors (Skewness, Kurtosis, frequency-domain features), particularly with motion artifacts.
- For arrhythmia data, beat analysis using sparse coding showed superior performance compared to simple periodicity tests.
- The developed methods reliably selected cardiac signals from spatio-temporal BSS outputs in the presence of severe artifacts and arrhythmias.
Conclusions:
- Automated component selection routines based on heartbeat detection effectively resolve permutation indeterminacy in spatio-temporal BSS.
- These robust selectors enable reliable cardiac signal extraction from artifact-sensitive minimum-contact vital signs monitoring.
- Facilitates the broader adoption of advanced BSS techniques in wearable health monitoring systems.
Related Concept Videos
Blind Procedures
13.6K
Ideally, the people who observe and record the children’s behavior are unaware of who was assigned to the experimental or control group, in order to control for experimenter bias. Experimenter bias refers to the possibility that a researcher’s expectations might skew the results of the study. Remember, conducting an experiment requires a lot of planning, and the people involved in the research project have a vested interest in supporting their hypotheses. If the observers knew which...
13.6K
Blinding
4.0K
Blinding is a commonly used method of not telling participants which treatment a subject is receiving. Blinding is a critical part of a randomized control trial or RCT. It reduces the bias that affects the results. In an RCT, blinding is used in the form of a placebo. A placebo effect occurs when untreated subjects falsely believe they have received the treatment and report improved symptoms. A placebo or a dummy treatment is administered to subjects to negate the bias caused by such an effect.
4.0K
Methods of Documentation I: Source-Oriented Records
1.7K
Source-oriented records, or SOR, are medical record-keeping organized by the data source. The SOR system was first developed in the mid-1900s to organize the growing patient data in hospitals and other healthcare facilities.
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
1.7K
Paracrine Signaling
59.7K
Paracrine signaling allows cells to communicate with their immediate neighbors via secretion of signaling molecules. Such a signal can only trigger a response in nearby target cells because the signal molecules degrade quickly or are inactivated if not taken up. Prominent examples of paracrine signaling include nitric oxide signaling in blood vessels, synaptic signaling of neurons, the blood clotting system, tissue repair/wound healing, and local allergic skin reactions. Nitric oxide as a...
59.7K
What is Natural Selection?
129.6K
Natural selection is an evolutionary process in which individuals with survival-promoting traits reproduce at higher rates. These favorable traits become more common within a population or species. Naturally selected traits initially arise via random genetic mutations. In order for selection to occur, there must be variation within a population, the trait controlling the variation must be heritable, and there must be an evolutionary advantage for variation in the trait.
129.6K
Antibiotic Selection
60.0K
Overview
60.0K