Accuracy of visual and image-based ICDAS criteria compared with a micro-CT gold standard for caries detection on
Raquel Nogueira de Carvalho1, Aline Dos Santos Letieri1, Thiago Isidro Vieira1
1Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Department of Pediatric Dentistry and Orthodontics, Rio de Janeiro, RJ, Brazil.
Abstract:
The aim of this study was to check the in vitro accuracy of ICDAS criteria on digital images compared to visual examination for the diagnosis of occlusal caries against a micro-CT gold standard. ICDAS was scored in 40 extracted permanent molars by means of visual inspection and stereomicroscopic images. Visual examinations were performed in duplicate and at a one-week interval by three different calibrated examiners. The analysis of digital images by ICDAS criteria was also performed in duplicate, 1 month after visual examinations. The detection methods were compared by means of sensitivity, specificity, area under the curve, predictive positive and negative values, and accuracy for two different thresholds (1- sound vs. carious teeth; 2- tooth requiring operative vs. non-operative treatment). Sensitivity and accuracy values for threshold 1 in the visual ICDAS and image-based ICDAS methods were high for sensitivity (0.93 and 0.97) and for accuracy (0.83 and 0.85), but low for specificity (0.55 for both methods). Specificity values for threshold 2 were 0.77 and 0.82, while sensitivity was 0.33 and 0.28 for each method. Spearman's rank correlation coefficient was 0.53 and 0.43 (p<0.05) for visual and image-based ICDAS compared to the gold standard scores. Both visual and image-based ICDAS scores were similar to each other in terms of diagnostic accuracy when compared to the micro-CT gold standard. Low specificity for the presence of caries and sensitivity for the detection of caries requiring operative treatment were found.
More Related Videos
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Criteria for Causality: Bradford Hill Criteria - II
Criteria for Causality: Bradford Hill Criteria - I
Improving Translational Accuracy
Imaging Studies for Cardiovascular System V: CT