Related Experiment Video
Updated: Feb 7, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Computer-assisted detection of tardus parvus waveforms on Doppler ultrasound
Gowthaman Gunabushanam1, John D Millet1,2, Erik Stilp3
1Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, USA.
Objective:
To determine if a novel computer-generated metric, effective acceleration time, improves accuracy for detecting tardus parvus waveforms on spectral Doppler ultrasound.
Methods:
Patients with echocardiography-confirmed aortic valve stenosis (n = 132; 60 mild, 44 moderate, 28 severe) and matched controls (n = 48) who underwent carotid Doppler ultrasound were identified through an imaging database search at a single medical center. A custom-built spectral analysis computer program generated effective acceleration time values for spectral Doppler waveforms in the carotid arteries and a receiver operating characteristic analysis was performed to determine the optimal median effective acceleration time cutoff value to detect tardus parvus waveforms. Two radiologists, blinded to subject disease status, reviewed and rated all carotid sonograms for presence of tardus parvus waveforms. Inter-rater variability was measured, and the accuracy of aortic valve stenosis detection with and without use of the effective acceleration time cutoff was calculated.
Results:
Receiver operating characteristic analysis revealed an optimal effective acceleration time cutoff of ≥ 48 ms with a corresponding area under the curve of 0.77 (95% CI: 0.70-0.84). Use of the effAT cutoff demonstrated an accuracy of 74%. Accuracy of visual waveform interpretation by raters ranged from 43% to 61%. Inter-rater agreement in detection of tardus parvus waveforms was 76% (136/180 cases, K = 0.44, p < 0.001).
Conclusions:
Detection of tardus parvus waveforms through visual interpretation of spectral Doppler waveform morphology is limited by low accuracy and moderate inter-rater variability. Use of a computer-generated median effective acceleration time cutoff value markedly improves diagnostic accuracy and avoids observer variability.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Doppler Effect - I
Doppler Effect - II
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...