Single-phase bilateral low dose contrast medium injection for diagnosing occlusions of the thoracic venous system: a
Anders Svensson1,2, Torkel B Brismar1,2, Fabian Morsbach1,2
1Department of Clinical Science, Intervention and Technology at KarolinskaInstitutet, Division of Medical Imaging and Technology, Stockholm, Sweden.
Abstract:
Occlusion of the thoracic venous system and/or occlusion of central venous catheters (CVC) of unknown cause can, in selected cases, require advanced imaging. Here, we describe a case study of a patient with a failing central dialysis catheter (CDC) which was diagnosed by computed tomography (CT) in connection with a single-phase bilateral low-dose contrast medium (CM) injection using only 3.6 g of iodine. By injecting a low CM dose, the risk of streak artifacts from first-pass of high intravascular concentrations of CM can be avoided. Therefore, the technique described here should be beneficial also to patients with normal renal function.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Power Distribution in Three-phase and Single Phase Circuits
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...