Related Experiment Video
Updated: Feb 7, 2026

Focal Laser Ablation of Prostate Cancer: An Office Procedure
Published on: March 30, 2021
Oncologic and Functional Outcomes of Partial Gland Ablation with High Intensity Focused Ultrasound for Localized
Roman Bass1, Neil Fleshner2, Antonio Finelli2
1Division of Urology, Sunnybrook Health Sciences Centre, University of Toronto , Toronto , Ontario , Canada.
Purpose:
We assessed the outcomes of high intensity focused ultrasound as primary treatment of localized prostate cancer in a retrospective series. This represents one of the largest published series of patients at intermediate and high risk.
Materials And Methods:
We performed a retrospective multicenter analysis of patients who underwent partial gland ablation between January 2013 and September 2017. Patients with biopsy proven localized disease and limited multifocality based on magnetic resonance imaging who preferred minimally invasive outpatient therapy were treated with the Sonablate® 500 system. Oncologic and functional outcomes were analyzed as well as risk factors for recurrence.
Results:
A total of 166 procedures were performed in 150 patients. Grade Group 2 or greater was present in 89% of cases. Mean ± SD followup was 24.3 ± 14.4 months. Mean prostate specific antigen decreased 65% from 7.9 ± 6.8 ng/ml to a nadir of 2.7 ± 3.1 ng/ml. Confirmatory biopsies were performed in 87 patients (52%) at high risk for recurrence. Clinically significant cancer (Grade Group 2 or greater) was detected in 37 cases (42%). Patients with a higher number of positive cores, a medial tumor location or higher prostate specific antigen had a higher probability of recurrence. Salvage treatment was done in 37 patients (24.6%), including 16 repeat partial gland ablation procedures.
Conclusions:
Partial gland ablation with high intensity focused ultrasound therapy was safe and it had a minimal impact on functional outcomes. Local recurrence and/or failure occurred in 42% of patients at high risk for recurrence. Medially located tumors were associated with a higher failure rate. Serious complications were rare. Whole gland treatment was avoided in 81% of patients.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
08:19Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications
Published on: October 5, 2018
Related Concept Videos
Integration of Rational Functions Using Partial Fractions
Partial Fractions
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Sound Intensity
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...