Related Experiment Video
Updated: Feb 7, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left
Kei Iizuka1,2, Tomohiro Nishinaka3, Daichi Akiyama4
1Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, Osaka, Japan. Iizuka.kei@twmu.ac.jp.
Abstract:
Aortic insufficiency (AI) is a crucial complication during continuous-flow left ventricular assist device (LVAD) support. Our previous clinical study suggested that a larger angle between the outflow graft and the aorta (O-A angle) could cause AI progression. This study examined the effect of the O-A angle on the hemodynamics of AI under LVAD support in an acute animal experimental model. An LVAD was installed in seven calves, with the inflow cannula inserted from the LV apex and with the outflow graft sutured at the ascending aorta. The AI model was made using a temporary inferior vena cava filter inserted from the LV apex and placed at the aortic valve. Cardiac dysfunction was induced by continuous beta-blocker infusion. Hemodynamic values and the myocardial oxygen extraction rate (O2ER) were evaluated at three O-A angles (45°, 90°, and 135°) over three levels of AI (none, Sellers I-II AI, and Sellers III-IV AI). The recirculation rate, defined as the percentage of regurgitation flow to LVAD output, was calculated. Systemic flow tended to decrease with a larger O-A angle. The recirculation rate was significantly increased with a larger O-A angle (22, 23, and 31% at 45°, 90°, and 135° in Sellers III-IV AI, respectively). Coronary artery flow was decreased at a larger O-A angle (86, 76 and 75 mL/min at 45°, 90°, and 135° in Sellers I-II AI, respectively, and 77, 67, and 56 mL/min at 45°, 90°, and 135° in Sellers III-IV AI, respectively). O2ER tended to increase with a larger O-A angle (40, 43, and 49% at 45°, 90°, and 135° in Sellers III-IV AI, respectively). A larger O-A angle can increase the recirculation due to AI and can be disadvantageous to LVAD-AI hemodynamics and myocardial oxygen metabolism.
Related Concept Videos
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
Role of Affect in Interpersonal Attraction
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
The Influence of Affect on Cognition
The Influence of Cognition on Affect