Objectives:
This prospective cohort study estimated the effect of technical and clinical factors on mechanical complications in implant-supported fixed complete dentures (IFCDs). The patient's perception of the impact of oral rehabilitation on quality of life was assessed.
Material And Methods:
A non-probabilistic sample consisted of 88 consecutive patients treated with 94 screw-retained, metal-acrylic IFCDs. Data collection included sociodemographic variables, presence and intensity of bruxism, maximal occlusal force, opposing arch, design of the metallic framework, distribution of occlusal contacts, and quality of life (OHIP-14). IFCD-level data were analyzed using Kaplan-Meier survival analysis and Cox regression model. Quality of life data were analyzed by paired Student t test.
Results:
During a mean follow-up of 35.1 ± 18.3 months, 16/94 IFCDs (17%) had repairable mechanical complications because of loosening/fracture of artificial teeth (n = 15) and screw loosening (n = 1). Framework design (retention pins <4 mm) was a significant risk factor for complications (HR = 11.038; p = 0.027) when adjusted for sex. Mechanical complications were not associated with sex, body mass index, thickness of the acrylic resin veneering, type of opposing arch, distribution of occlusal contacts and force, protrusion interference, presence/intensity of bruxism or maximal occlusal force. OHIP-14 total scores decreased after IFCD treatment for both patients with or without complications.
Conclusions:
Within the limitations of this study, the results suggest that clinical success is associated to framework design with retention pins equal or longer than 4 mm. Quality of life improved with IFCD treatment, even in patients with mechanical complications.
More Related Videos
03:05Influence of Emotional Factors on the Efficacy of Acupuncture Treatment for Overweight Complicated with Hyperlipidemia: A Retrospective Cohort Study
Published on: November 21, 2025
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Fixed Action Patterns
The Quantum-Mechanical Model of an Atom
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Fixing Double-strand Breaks
Hemodialysis II: Procedure and Complications