Related Experiment Video
Updated: Feb 7, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
How a pilot hole size affects osteosynthesis at the screw-bone interface under immediate loading
F Affes1, H Ketata2, M Kharrat2
1Laboratory of Electromechanical Systems, National Engineering School of Sfax, Sfax University, PO Box 1173, 3038 Sfax, Tunisia.
Abstract:
An inappropriate pilot hole size (PHS) is one of several factors that affects the stiffness of the screw-bone fixation. The present study uses finite element models to investigate the effect of varying the PHS on the biomechanical environment of the screw-bone interface of the fractured bone, after the screw insertion and under the immediate body weight pressure (BWP). Four PHS from 71% up to 85% of the screw external diameter (SED) were considered for analysis. A non linear material behaviour of the bone with ductile damage properties was used in the study. To validate the numerical models, an experimental pull-out test was carried out using a synthetic bone. The results of the insertion process demonstrated that the relatively smaller holes (71% and 75.5% of SED) increased the insertion torque value within the recommended level, caused more bone radial extension deformation and maximized the contact area between the bone threads and the screw, in comparison to the PHS higher than 80% of SED. Under the immediate BWP after osteosynthesis, the stress level exceeds the elastic limit and becomes high enough to initiate the ductile damage of the bone. Also, enlarging PHS from 71% to 75.5% of SED increased the bone microdisplacement at the screw-bone interface from 75 up to 100 μm, and that reduced the stiffness of the fixation.
More Related Videos
09:09Treatment with Vancomycin Loaded Calcium Sulphate and Autogenous Bone in an Improved Rabbit Model of Bone Infection
Published on: March 14, 2019
07:33In Vivo Evaluation of Fracture Callus Development During Bone Healing in Mice Using an MRI-compatible Osteosynthesis Device for the Mouse Femur
Published on: November 14, 2017
Related Concept Videos
Pilot and Numeric Relaying
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Protein-protein Interfaces
Protein-Protein Interfaces
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...