Evaluation of absorbable PLA nasal implants in an ovine model
Marian K Rippy1, Scott Baron2, Mike Rosenthal2
1Rippy Pathology Solutions Woodbury Minnesota U.S.A.
Objective:
To examine biocompatibility and absorption profile of a poly (L-lactide-co-D,L-lactide) 70:30 nasal implant.
Methods:
In an ovine model, 66 rod-shaped absorbable implants were placed in 11 nasal dorsa. The sheep were sacrificed at 1.5 (N = 3), 6 (N = 3), 12 (N = 3), 18 (N = 1), and 24 months (N = 1). The nasal dorsum was harvested from each animal. Gross and histopathological examinations were performed.
Results:
There were no postoperative complications, signs of infection, or tissue rejection throughout follow-up time points. Upon sacrifice, no abnormalities were identified during gross pathological examinations. The histology of the implant sites at all time points showed the implants were fully encapsulated through 12 months. The inflammatory reaction to the implants was minimal to mild at 1.5, 6, and 12 months. At 18 months the implant material was in the mass loss phase, being actively absorbed. During this phase, the inflammatory reaction within the fibrous connective tissue capsule reached expected moderate levels. By 24 months, the inflammatory reaction had diminished in most implantation sites and complete absorption of the rod implants was noted at some sites with nodular bundles of mature collagenized fibrous tissue replacing the implant, devoid of an inflammatory infiltrate.
Conclusion:
Biocompatibility of the poly (L-lactide-co-D,L-lactide) 70:30 material was demonstrated when used as a nasal implant in the nasal dorsum ovine model. Absorption of the implant occurred approximately 18 to 24 months postoperatively, and the implant site was replaced with collagenized fibrous tissue.
Level Of Evidence:
NA.
More Related Videos
07:25Ovine Lumbar Intervertebral Disc Degeneration Model Utilizing a Lateral Retroperitoneal Drill Bit Injury
Published on: May 25, 2017
07:33Preparation, Characteristics, Toxicity, and Efficacy Evaluation of the Nasal Self-Assembled Nanoemulsion Tumor Vaccine In Vitro and In Vivo
Published on: September 28, 2022
Related Concept Videos
Nose and Nasal Cavity
Self-Evaluation Maintenance Model
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Self-Evaluation: Self-Enhancement and Self-Verification
The Bohr Model